Root Stock Wine Design
Ceiling Mount 4000 1000 Cubic Feet
Ceiling Mount 4000 1000 Cubic Feet
Couldn't load pickup availability
EVAPORATOR
Model 4000
Cellar Size 1000 cu. ft
Fan Speed Medium | High
BTU/h (60°F condenser air intake temperature) Sensible / Total 4871 / 5430 | 5324 / 6087
BTU/h (75°F condenser air intake temperature) Sensible / Total 4752 / 5291 | 5198 / 5914
BTU/h (85°F condenser airintake temperature) Sensible / Total 4631 / 514 | 4945 / 5351
dBA 48 | 53
Dimensions 35.75”L x 14.5”W x 12.75”H
Refrigerant R-134a
Voltage Rating 120V (15-amp dedicated circuit required)
Weight (lbs) 66
Amps 1.4 (Running Amps)
Drain Line 1/4″ ID clear plastic tubing (not provided) – Rigid tube recommended
Installation Evaporator unit is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V – customer supplied
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)
CONDENSER
Model 4000
dBA 45
Dimensions 31.18″L x 10.75″W x 21.18″H
Condensing Unit HP 0.6HP
Voltage Rating 220V (15-amp dedicated circuit required)
Weight (lbs) 55
Amps LRA 10.7, RLA 2.7, FLA 3.1
Line Set Liquid line 1/4” OD; Suction line 1/2” OD (less than 50 ft.), 5/8” (greater than 50 ft.)
Installation Evaporator unit is installed in the cellar. The condensing unit is installed up to 100 line feet from the evaporator unit.
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Warranty Two-year limited warranty (parts and labor)
Share








Subscribe to our emails
Subscribe to our mailing list for insider news, product launches, and more.